A professional Sound Pressure Level (SPL) meter built with JUCE, available as a macOS/Windows/Linux standalone app and as VST3 / AU plugin. Since v3.6 it also measures vibration with an IEPE accelerometer, alongside the microphone.
- Broadband SPL in dB, dB(A), and dB(C) — peak and RMS simultaneously
- IEC 61672-compliant time weighting: FAST (125 ms) and SLOW (1 s)
- Configurable calibration offset (80–140 dB, default 127 dB)
- Adjustable peak hold time
- Optional 20 Hz – 20 kHz bandpass filter (8th-order Butterworth, 48 dB/oct)
- Large horizontal bargraph meter (20–130 dB SPL scale)
- Numeric SPL readout with peak-hold indicator
- Basic / Advanced mode toggle — Basic shows only the SPL meter; Advanced adds the full log plot and psychoacoustic overlay
- Time-series log plot with per-series visibility toggles (Left y-axis: dB / dB(A) / dB(C))
- Selectable psychoacoustic overlay on the right y-axis: Roughness, Fluctuation Strength, Sharpness, Specific Loudness, Psychoacoustic Annoyance
- ML-powered sound event detection; opened via the Tools… menu
- Apple platforms (macOS / iOS): uses Apple SoundAnalysis framework for on-device neural classification
- All platforms: optional user-supplied TFLite model (
.tflite) loaded at runtime — supports any 1-D audio input model (e.g. YAMNet); auto-detects a matching_labels.txtfile in the same directory; configurable model sample rate (default 16 kHz) - Falls back to a heuristic amplitude-onset detector when no ML framework or model is available
- Configurable minimum confidence threshold (0.10 – 0.90)
- Scrollable event log — timestamp, label, confidence for each detected event; auto-trims to 500 events
- Timeline markers — detected events appear as labelled vertical markers on the log plot
- Clear button resets both the event log and the timeline markers simultaneously
- Save Events CSV export
- Opened via the Tools… menu; floating window with configurable controls
- Frequency scale: Log (default) or Mel
- Gain and time-resolution controls
- FFT size: 32 – 524,288 samples (14 selectable sizes), configurable in Settings
- Toggled via the FFT button; displayed as a semi-transparent overlay on the log plot
- Unweighted (raw) signal — A/C weighting is not applied
- FFT size: 32 – 524,288 samples (14 selectable sizes), configurable in Settings
- Band resolution: 1/1, 1/3, 1/6, 1/12, or 1/24 octave (up to ~240 bands)
- Display modes: Bars, Area fill, Bars + Peak hold markers
- Window functions: Hann, Hamming, Blackman, Flat-top, Rectangular
- Overlap: 0 %, 25 %, 50 %, 75 %
- RTA +3 dB/oct mode — applies a +3 dB/octave tilt so pink noise appears flat
- Frequency axis labels (20 Hz – 20 kHz) along the FFT x-axis
Continuous real-time estimation of:
| Metric | Description |
|---|---|
| Roughness | Perceived roughness / beating (15–300 Hz AM range) |
| Sharpness | High-frequency spectral centroid (acum, Zwicker/Aures model) |
| Fluctuation Strength | Slow amplitude modulation (0.5–20 Hz range) |
| Specific Loudness | Perceived loudness approximation (sone) |
| Psychoacoustic Annoyance | Combined annoyance index (Zwicker & Fastl 1999): N × (1 + √(w_S² + w_FR²)) |
Full guide: docs/VIBRATION_GUIDE.md
- One IEPE accelerometer (triaxial or uniaxial) plus the microphone at the same time — each input gets a role (Mic, Accel X/Y/Z, Accel uniaxial, Off) in Settings → Inputs and Sensors…; only Mic inputs feed the SPL meter
- Calibration per axis with a handheld calibrator (10 m/s² / 1 g at 159.2 Hz, or custom) or from the datasheet sensitivity and the interface's full scale
- Signal chain in double precision: high-pass, integration to velocity or displacement, ISO 8041 frequency weightings (Wb, Wc, Wd, We, Wf, Wh, Wj, Wk, Wm), DIN 4150-2 KB weighting, or a band limit
- Detectors: running RMS, peak, peak-to-peak, a_w,rms, MTVV, VDV, crest factor, PPV with dominant frequency, KB_Fmax / KB_FTr, vector sum with k-factors, A(8), 1/3-octave spectrum (1 Hz – 1250 Hz)
- Measurement profiles: structure-borne, machinery (ISO 20816), whole-body health and comfort (ISO 2631-1), hand-arm (ISO 5349-1), building perception (DIN 4150-2), building structural (DIN 4150-3)
- Assessment against editable reference values: EU 2002/44/EC and German LärmVibrationsArbSchV action/limit values, ISO 10816-3 / 20816-3 zones A–D, DIN 4150-2 A_u / A_o / A_r, DIN 4150-3 guideline values; shown as a status dot in the panel
- Vibration panel below the SPL meter, timeline traces (Vib X · Y · Z · Σ), vibration CSV columns, multichannel WAV with roles and calibration, and an HTML vibration report
- Indicative measurements: SPLMeter is not a type-tested ISO 8041-1 / DIN 45669-1 instrument
Full guide: docs/REW_SEQUENCER_GUIDE.md
- Tools → REW Measurement Sequencer… runs a list of Room EQ Wizard sweep measurements one after the other through REW's REST API (REW Pro, API enabled, same computer)
- Per step: name and notes, output, second output (ASIO) / invert, input range, level, sweep range and length, repetitions, timing reference, clipping / SPL-limit protection, REW group, wait for me prompt, delay; unset settings keep REW's value
- Add positions… for multi-position measurements, loops, gap between steps, stop / skip / retry on errors, dry run, pause and abort; REW's settings are restored after the run
- SPLMeter measures each sweep too: LAeq, LCeq, LZeq, LAFmax, LCSmax, LCpeak and, with an accelerometer, vibration RMS and peak per axis — saved with the run as CSV and JSON, plus one timeline marker per sweep
- Sequences are saved as
*.rewseq.json; the run continues when the window or editor is closed
- Real Time — live microphone / audio interface input, up to 32 channels; each input can be a microphone or an accelerometer axis
- File — load and analyse an audio file (WAV, AIFF, FLAC, MP3, OGG)
- Monitor button — speaker icon; output is muted by default, click to enable pass-through
Accessible via the Ex-/Import… button (popup menu):
- Save CSV — exports the full measurement log (timestamps, all SPL values, all psychoacoustic metrics; with an accelerometer also the vibration values) as a CSV file
- Save WAV — saves the last Keep Last seconds of Input 01 and 02 as a stereo 24-bit WAV file; with an accelerometer, every non-Off input (up to 8 tracks) with roles and calibration in the file
- Save Screenshot — exports the current view as a JPEG image
- Save All — saves CSV, WAV, and screenshot in one step into a chosen folder
- Save Vibration Report — one self-contained HTML file (setup, results, assessment, charts, events, disclaimer), printable to PDF
- Save / Load Settings — JSON file with all settings, including input roles, accelerometer calibration and assessment values
Accessible via the Tools… button (popup menu):
- Spectrogram — opens the spectrogram floating window (Log or Mel frequency scale)
- SoundDetective — ML-powered sound event detection (Apple SoundAnalysis on Apple platforms; optional TFLite model on all platforms; heuristic fallback)
- ViSQOL (macOS / Windows when pre-built lib is present) — perceptual audio quality analysis (MOS-LQO + per-band NSIM)
- Correction Filter — load a frequency-response correction curve (.txt / .csv: Hz + dB pairs); applied as a linear-phase FIR filter before metering (configured in Settings)
- Graph Overlay — load a reference curve and display it as a dashed blue line in the FFT view (configured in Settings)
- REW Measurement Sequencer (not on iOS) — runs a list of REW sweep measurements with per-step settings and measures each sweep with SPLMeter (see above)
- Live clock — auto-updating date/time display (updates every second)
- Note field — three-line free-text field for session annotations
Opened via the Settings button. A wide, two-column, card-based window with a one-line description under each section header — organised into five sections:
| Section | Contents |
|---|---|
| General | Calibration fader, Hold Time fader, Light Mode, 94 dB Reference Line, 20–20k Bandpass, Full Screen |
| FFT | FFT enable toggle, FFT Gain fader, FFT Smooth fader, FFT Size (32 – 524,288 samples), Band Resolution, Display Mode, Window Function, Overlap, Peak Hold, RTA +3 dB/oct |
| Spectrogram | FFT Size (32 – 524,288 samples) for the Spectrogram window |
| Analysis | Correction Filter (enable / load / clear), Graph Overlay (enable / load / clear) |
| Input Channels | Per-channel mute buttons for IN01 – IN32 (with the role tag), Inputs and Sensors… window for roles, accelerometer calibration, profile and assessment |
Right-click any of the three faders to assign or clear a MIDI CC mapping:
- Calibration — dB offset
- FFT Gain — FFT input gain
- Hold Time — peak hold duration
Assigned CC numbers are shown next to each fader label (e.g. [CC 4]).
| Control | Description |
|---|---|
| Basic Mode / Advanced Mode | Toggle between compact meter-only view and full advanced view |
| FAST / SLOW | IEC 61672 time weighting |
| Real Time / File | Input source |
| Monitor (speaker icon) | Enables audio pass-through output; OFF by default |
| Settings… | Opens the settings panel |
| Calibration | dB offset to convert full-scale to SPL (right-click for MIDI learn) |
| Hold Time | Peak hold duration in seconds (right-click for MIDI learn) |
| FFT Gain | Input gain for the FFT overlay (right-click for MIDI learn) |
| FFT Smooth | Spectral smoothing factor (0 = off, 0.95 = heavy) |
| FFT | Toggle FFT spectrum overlay on/off |
| 20-20k BP | Enable 8th-order Butterworth bandpass filter |
| 94 dB Line | Draw a dashed reference line at 94 dB SPL in the log plot |
| Light Mode | Switch to light theme |
| Left y axis checkboxes | Visibility of dB SPL / dBA SPL / dBC SPL series |
| Right y axis checkboxes | Psychoacoustic overlay: Roughness / Fluctuation / Sharpness / Specific Loudness / Annoyance |
| Save… | Popup menu: Save CSV / Save WAV / Save Screenshot / Save All |
| Tools… | Popup menu: Spectrogram / SoundDetective / ViSQOL (macOS/Windows) |
| Reset | Clear log and reset peak holds |
| Clock | Live date/time (updates every second) |
| Note field | Free-text annotation field (3 lines) |
┌─────────────────────────────────────────────────────────────────────────────┐
│ ppkSPLmeter v3.5 — Real-Time Audio Signal Flow │
└─────────────────────────────────────────────────────────────────────────────┘
┌──────────────┐ ┌──────────────────────┐
│ DAW / Host │ │ File Transport │
│ Input Bus │ │ AudioTransportSource │
│ (≤32 ch) │ │ (file playback mode) │
└──────┬───────┘ └──────────┬───────────┘
│ │
└──────────┬─────────────┘
│ source selection
▼
┌──────────────────┐
│ Channel Muting │ (per-channel on/off, up to 32 ch)
└────────┬─────────┘
│
├──────────────────────────────────────────────────────────┐
│ │
▼ WAV Capture
┌──────────────────────┐ (pre-EQ)│
│ WAV Circular Buffer │ ◄── Ch0 + Ch1, pre-filter │
│ (lock-free ring buf)│ │
│ → Save WAV feature │ │
└──────────────────────┘ │
│ │
▼ │
┌──────────────────────────────────────┐ │
│ Bandpass Filter (optional) │ │
│ 8th-order Butterworth 20Hz – 20kHz │ │
│ 4× cascaded biquad (HP + LP stages) │ │
│ per active channel │ │
└──────────────────┬───────────────────┘ │
│ │
▼ │
┌──────────────────────────────────────┐ │
│ FIR Correction Filter (optional) │ │
│ 4096-tap linear-phase │ │
│ juce::dsp::Convolution │ │
│ (inverted measured SPL curve) │ │
└──────────────────┬───────────────────┘ │
│ │
▼ │
┌─────────────────┐ │
│ Mono Mix │ Σ(all active ch) / N │
└────────┬────────┘ │
│ │
┌───────────────┼─────────────────────────────────────┐ │
│ │ │ │ │
▼ ▼ ▼ ▼ │
┌──────────────┐ ┌─────────────┐ ┌───────────────┐ ┌────────────────┐ │
│ A-Weighting │ │ C-Weighting │ │ FFT Circular │ │ Psychoacoustic │ │
│ IIR filter │ │ IIR filter │ │ Buffer │ │ Estimators │ │
│ (IEC 61672) │ │ (IEC 61672)│ │ 8192 samples │ │ │ │
└──────┬───────┘ └──────┬──────┘ │ lock-free │ │ • Roughness │ │
│ │ │ atomic write │ │ (AM 15-300Hz│ │
│ │ └───────┬───────┘ │ • Sharpness │ │
│ │ │ │ (Zwicker/ │ │
│ │ │ │ Aures 8-bd)│ │
│ │ │ │ • Fluctuation │ │
│ │ │ │ (0.5-20 Hz) │ │
│ │ │ └───────┬────────┘ │
│ │ │ │ │
└───────┬─────── ┘ │ │ │
│ │ │ │
▼ ▼ ▼ │
┌─────────────────────┐ ┌────────────────┐ ┌───────────────────┐ │
│ Peak Tracking │ │ FFT spectrum │ │ Psychoacoustic │ │
│ with Hold │ │ → GUI display │ │ readouts │ │
│ (raw, A, C) │ │ (30 Hz poll) │ │ → GUI atomics │ │
│ configurable hold │ └────────────────┘ └───────────────────┘ │
└──────────┬──────────┘ │
│ │
▼ │
┌──────────────────────────────────────┐ │
│ Exponential RMS Smoothing │ │
│ IEC 61672 time weighting │ │
│ FAST τ = 125 ms │ │
│ SLOW τ = 1000 ms │ │
│ (raw, A-weighted, C-weighted) │ │
└──────────────────┬───────────────────┘ │
│ │
▼ │
┌──────────────────────────────────────┐ │
│ Atomic Readout Update (every 125ms) │ ◄── also pushes LogEntry │
│ • SPL raw/A/C (fast+slow) │ to deque │
│ • Peak raw/A/C │ (pruned to logDuration) │
│ • Psychoacoustic values │ │
└──────────────────┬───────────────────┘ │
│ │
▼ │
┌─────────────────┐ │
│ Monitor Mute │ buffer.clear() if monitor off │
└────────┬────────┘ │
│ │
▼ │
┌─────────────────┐ │
│ DAW / Host │ │
│ Output Bus │ │
└─────────────────┘ │
│
┌────────────────────────────────────────────────────────────────────────────┘
│ GUI Timer (30 Hz)
│ ┌──────────────────────────────────────────┐
└─►│ timerCallback() │
│ • reads atomics → MeterComponent │
│ • reads FFT ring buf → spectrum display │
│ • updates Log / CSV export │
│ • MIDI CC learn / apply │
└──────────────────────────────────────────┘
Requires Xcode and the JUCE framework.
DEVELOPER_DIR=/Applications/Xcode.app/Contents/Developer \
xcodebuild -project Builds/MacOSX/SPLMeter.xcodeproj \
-scheme "SPLMeter - Standalone Plugin" \
-configuration Release buildAfter building in an iCloud-synced directory, re-sign before launching:
xattr -cr Builds/MacOSX/build/Release/SPLMeter.app
codesign --force --sign - Builds/MacOSX/build/Release/SPLMeter.app
open Builds/MacOSX/build/Release/SPLMeter.appcmake -B build -DCMAKE_BUILD_TYPE=Release
cmake --build build --config ReleaseASIO support is enabled automatically — CMake downloads the Steinberg ASIO SDK 2.3.3 during configuration if it is not already present locally.
To use a local copy instead, place the unzipped SDK root at Vendor/asiosdk/ inside the project root, or pass the path explicitly:
cmake -B build -DASIO_SDK_DIR="C:/path/to/asiosdk/common" -DCMAKE_BUILD_TYPE=ReleaseGitHub Actions workflows build the standalone for macOS and Windows on every push.
- macOS 10.13+ (Apple Silicon native) or Windows 10+
- Audio input device for Real Time mode
| Library | Version | License | URL |
|---|---|---|---|
| JUCE | 8.0.7 | ISC / GPL-3.0 | https://github.com/juce-framework/JUCE |
| Steinberg VST3 SDK (incl. ASIO SDK) | latest | Steinberg VST3 License | https://github.com/steinbergmedia/vst3sdk |
| Room EQ Wizard REST API (used by the REW Measurement Sequencer; REW is not bundled) | API 0.9.9 (REW 5.40) | REW EULA | https://www.roomeqwizard.com/help/help_en-GB/html/api.html |
| Reference | Description |
|---|---|
| IEC 61672-1:2013 | Electroacoustics — Sound level meters. Defines FAST (125 ms) and SLOW (1 s) time weighting and A/C frequency weighting curves. |
| ISO 266:1997 | Preferred frequencies — defines the 31 standard 1/3-octave band centre frequencies (20 Hz – 20 kHz). |
| Zwicker & Fastl, Psychoacoustics: Facts and Models (3rd ed., Springer, 2007) | Theoretical basis for the Roughness, Sharpness, Fluctuation Strength, Specific Loudness, and Psychoacoustic Annoyance estimators. |
| ISO 8041-1, ISO 2631-1/-2/-4, ISO 5349-1 | Human vibration frequency weightings and evaluation (a_w, MTVV, VDV, A(8), comfort scale). |
| Directive 2002/44/EC, LärmVibrationsArbSchV | Whole-body and hand-arm exposure action and limit values (EU, Germany). |
| ISO 10816-3 / ISO 20816-3 | Machinery vibration severity zones A–D. |
| DIN 4150-2, DIN 4150-3 | Building vibration: effects on people (KB weighting, A_u / A_o / A_r) and on structures (PPV guideline values). |
| IEC 61260-1 | 1/3-octave band centre frequencies (base 10) of the vibration spectrum. |
Sources and verification status of all vibration parameters: docs/VIBRATION_SPEC.md §14.
- Vibration measurement with an IEPE accelerometer alongside the microphone — see docs/VIBRATION_GUIDE.md
- Inputs and Sensors window (Settings → Input Channels): a role per input (Mic, Accel X/Y/Z, Accel uniaxial, Off), live level meters, per-axis calibration (handheld calibrator or datasheet) with date and method
- Accelerometer signal chain: high-pass, integration to velocity / displacement, ISO 8041 weightings (Wb, Wc, Wd, We, Wf, Wh, Wj, Wk, Wm), DIN 4150-2 KB weighting, band limit; detectors for RMS, peak, a_w,rms, MTVV, VDV, crest factor, PPV with dominant frequency, KB_Fmax / KB_FTr, vector sum, A(8), 1/3-octave spectrum
- Measurement profiles for structure-borne sound, machinery, whole-body health and comfort, hand-arm, building perception and building structural
- Assessment with editable reference values (EU / Germany, ISO 20816-3, DIN 4150-2, DIN 4150-3) and a status dot in the new Vibration panel below the SPL meter
- Timeline vibration traces, CSV vibration columns, JSON settings with roles, calibration and limits
- Multichannel WAV recording with roles and calibration in the file; file playback uses them
- HTML vibration report (Ex-/Import → Save Vibration Report…)
- REW Measurement Sequencer (Tools → REW Measurement Sequencer…): runs a list of Room EQ Wizard sweeps through REW's REST API with per-step output, second output / invert, inputs, level, sweep, repetitions, timing reference, protection, group and wait for me prompts; dry run, pause, abort, loops, error policy; REW's settings restored afterwards. SPLMeter measures every sweep (LAeq … LCpeak, vibration per axis) and saves the run as CSV and JSON, with a timeline marker per sweep — see docs/REW_SEQUENCER_GUIDE.md
- FFT source selector (mix, Dual 1+2, or a single input) replaces the Dual FFT toggle; v3.5.2 settings load unchanged
- The standalone app now accepts devices that open more than 8 inputs (up to 32); before, they fell back to a single input
- Default behaviour without accelerometer roles is unchanged (bit-identical SPL results, verified by regression tests)
- All user settings now persist across launches — previously some changes were silently reverted on quit, because the app's preferences shared a file with JUCE's standalone wrapper, which rewrote it from a stale copy. Preferences now live in their own
SPLMeter.prefs(migrated automatically) and are saved every few seconds, so they also survive a crash or force-quit. Newly remembered: window size, timeline series checkboxes and psychoacoustic metric, FFT overlay toggle, Spectrogram view settings, Long-term SPL toggles and Y range, Sound Detective threshold and TFLite model, Impulse Fidelity frequency, loaded correction filter and graph overlays, MIDI CC assignments and channel names - Dual FFT (Settings → FFT): the timeline FFT overlay can show separate spectra for input 1 (green) and input 2 (red), overlaid with a legend. Both use identical analysis settings; the crosshair reads out both levels
- FFT Size is now configurable for both the L_FFT timeline overlay (1024–8192, default 8192) and the Spectrogram (512–4096, default 2048) — previously the L_FFT engine was hardcoded to 8192 samples and the Spectrogram's size control was a local, non-persisted setting. Both are now proper APVTS parameters exposed as dropdowns in Settings and saved with the session
- Settings window redesigned: wider two-column, card-based layout (GENERAL / FFT on the left, SPECTROGRAM / ANALYSIS on the right, INPUT CHANNELS spanning the full width below), with each section getting a one-line description of what it controls
- Unweighted Peak readout added to the main SPL values line (after LAeq / LCeq) — shows the Z-weighted (flat, unweighted) instantaneous peak hold in dB SPL, complementing the time-weighted RMS and energy-averaged readouts. Contributed by Sokel.
- Timeline now matches the readouts — the SPL/dBA/dBC series in the time-series plot were plotting the peak-held values while the single-value readouts show time-weighted RMS, causing the timeline to overreport by the crest factor (~+4 dB). The plot now uses the RMS levels. Contributed by Miracle_Nosh.
- Bass comfort (LCeq − LAeq) time-series added to the timeline — plots the C-minus-A level delta over time on the right axis (dB), a low-frequency-content indicator. Contributed by icemac.
- TA Laerm compliance lane added next to DIN 15905-5 and NIOSH on the bottom strip — Beurteilungspegel
Lr(≈ LAeq) compared against day (06–22) / night (22–06) limits for the selected German land-use category, with an OK / WARN / LIMIT pill of its own. Categories: Industriegebiet, Gewerbegebiet, Misch-/Dorf-/Kerngebiet, Allg. Wohngebiet (default), Reines Wohngebiet, Kurgebiet/Krankenhaus - Settings → General: TA Laerm Category dropdown
- Hover tooltips on each compliance section (DIN 15905-5 / NIOSH / TA Laerm) explain what the values measure, the relevant limits, and the assumed measurement position.
MeterComponentnow implementsjuce::TooltipClient, capturing per-section bounds during paint and returning region-aware tooltip text
- Main meter now displays time-weighted RMS (IEC 61672 SPL) instead of held sample peak. Bargraph hold tick captures the maximum recent RMS reading (Lmax-style). Calibration with a 94 dB / 1 kHz reference now reads 94 dB on the meter as expected
- NIOSH REL readout alongside DIN 15905-5 in the same meter strip — cumulative 8-hour noise dose (3 dB exchange rate, 85 dB(A) criterion, 80 dB(A) threshold) with its own OK / WARN / LIMIT pill (50 % WARN, 100 % LIMIT, plus 140 dB(C) LCpeak ceiling); same dose readout in the Long-term SPL window after offline analysis
- DIN 15905-5 strip is Advanced-mode only and now sits below the Annoyance row of the psychoacoustic table; "LAeq,30min" relabelled to "LAeq(30min)"
- "Cal to Input" mirrored in the Long-term SPL window — calibrates
calOffsetso the loaded file's LAeq reads 94 dB(A) and auto-runs Refresh - Long-term SPL: spacebar play/pause kept (now also closes file mode cleanly when window is dismissed): closing the window stops playback and reverts the meter to the live input
- Title-bar Real Time / File buttons reflect file-mode state — light up automatically when Long-term SPL playback starts, revert to Real Time on stop, window close, or end-of-file
- First-launch defaults: only dBA SPL trace selected; psychoacoustic overlay starts off
- Output VU meter vertically aligned to the volume knob's textbox baseline
- DIN 15905-5 compliance readout — new strip in the main meter showing the sliding 30-min A-weighted equivalent continuous level (LAeq,30min) and the session-long C-weighted peak (LCpeak), each color-coded against the standard's thresholds (green / yellow at 95 dB(A) / 130 dB(C) / red at 99 dB(A) / 135 dB(C)) plus an OK / WARN / LIMIT compliance pill
- DIN 15905-5 in Long-term SPL — after offline file analysis, the worst-case sliding-30-min LAeq and the overall LCpeak (max |x_C|) are computed and shown beneath the existing stats line, with the same color-coded compliance status
- Session LCpeak —
peakDBCSPLis now also accumulated as a session-long maximum (independent of the regular peak-hold time) and reset by the Reset button or a FAST/SLOW switch
- Output VU meter — vertical L/R peak bargraph next to the master volume control; -60..+6 dBFS scale with green / yellow / orange / red zones, fast attack and ~250 ms release smoothing, 0 dBFS reference tick
- Master volume as 270° rotary knob — replaces the linear fader in the title bar; maximum gain raised from +12 dB to +32 dB
- Ctrl/Cmd+M shortcut — toggles the monitor (output) mute from anywhere in the main window
- Cal to Input button (Settings → General) — one-click calibration: averages the energy of the last ~2 s of input and sets the Calibration offset so it reads 94 dB SPL; intended for users without adjustable hardware input gain or who prefer not to use the Calibration slider directly
- Long-term SPL: Refresh button — re-runs the analysis on the loaded file with the current Calibration value, without reloading the file
- Long-term SPL: Spacebar toggles play/pause — works regardless of which transport button was last clicked
- Long-term SPL: file audio routed to the device output — pressing Play in the Long-term SPL window now actually plays the loaded file through the configured output (previously the live input was sent to the output during file analysis)
- Long-term SPL — new sub-app (Tools menu) for offline analysis of WAV / BWF files; computes A-, C-, and Z-weighted IEC 61672 FAST SPL across the full file with a waveform overview, zoomable time and dB axes, transport with playhead, click-to-seek, BWF timecode support, and CSV export; shares the main monitor controls
- Impulse Fidelity — new sub-app (Tools menu) for testing the transient response of a device under test using 1/3-octave tone bursts (100 Hz – 10 kHz); shows envelope comparison plots and computes attack, release, and overshoot metrics with a rating system
- L_FFT spectrum analyzer — new sub-app (Tools menu) showing a real-time 1/N octave band spectrum with log-frequency axis and dB SPL y-axis; reads all FFT settings from the Settings pane (window type, band resolution, smoothing, gain, RTA mode, display mode, peak hold, freq range)
- FFT snapshot storage — capture the current spectrum with the ✎ button; snapshots are listed in a sidebar with timestamp names, colour dots, and visibility toggles; click a snapshot to show/hide, right-click or Delete to remove; Cmd+Z undoes deletions
- Per-snapshot styling — gear icon on each snapshot opens a settings panel to change the overlay colour (10 swatches) and line style (solid, dashed, dotted, dash-dot)
- FFT cycle averaging — editable "Avg N" field (1–999) in the Settings FFT section; averages N consecutive FFT frames before computing band energies for a smoother display; applied in both the main FFT view and L_FFT
- FFT frequency range in Settings — f Lower / f Upper sliders moved from the right-click callout into the FFT section as vertical sliders; upper frequency limit extended to 100 kHz
- L_FFT Y-axis zoom — magnifying glass opens a callout to set the dB SPL display range (own parameters, independent of the main SPL plot)
- Hold time editing — clicking the hold time label in the title bar now shows only the numeric value in the editor (not the full "Hold time: X s" text)
- Settings pane widened to 720px; bandpass button renamed to "20Hz–20kHz Bandpass"
- Fix crash when loading correction filter — the convolution engine was prepared for 8 channels but the audio buffer could have 18+, causing a null-pointer dereference on the audio thread; also fixed a race condition where the IR was used before async background processing completed
- FFT crosshair cursor — click in the FFT plot to show a crosshair snapping to the nearest octave band with frequency and level readout; follows the mouse, adapts to light/dark mode
- Right Y-axis zoom for psychoacoustic metrics — each of the 7 metrics has independent min/max range parameters; magnifying glass icon next to the unit label opens a popup to adjust the displayed range; ranges saved/restored with plugin state
- Pause button tooltip — shows "Pause / Resume (M)" on hover
- Marker system — red diamond button in the title bar (Shift+M shortcut) to place named markers on the timeline; markers included in CSV export
- LAeq / LCeq — energy-averaged dBA/dBC over the log duration window, displayed in the meter readout and CSV export
- Unit test infrastructure — Catch2 v3.7.1 with 93 test cases covering DSP filters, psychoacoustic estimators, SPL calculations, state serialization, markers, and Leq
- Pause button & DAW sync moved to advanced-mode only
- SPL Y-axis zoom — magnifying glass icon below the "dB SPL" label opens a callout to set the minimum and maximum displayed dB SPL range; grid lines and labels update dynamically
- X-axis duration & FFT freq popup — the "Keep last (s)" bottom control is replaced by a magnifying glass at the centre of the time axis; clicking it opens a combined callout with time range (s), FFT lower frequency (Hz), and FFT upper frequency (Hz)
- FFT adjustable frequency range — lower and upper frequency limits (10–20 kHz) configurable via right-click on the FFT button in Settings; displayed range and axis labels update accordingly; persisted in APVTS and JSON settings
- Pause timeline markers — pausing and resuming analysis leaves a yellow dashed vertical line on the timeline with a flag showing the pause duration (e.g. "5s pause"); clock label now shows the wall-clock time of the last recorded data point and freezes while paused
- Input channel rename — right-click any channel button in Settings to rename it; names are saved with the project state
- Ex-/Import menu — Save Settings… and Load Settings… options export/import all parameters, UI state, channel names, and MIDI CCs as a human-readable JSON file
- Last-used folder memory — all file pickers remember the last-used folder
- Maximize button — standalone window now has a third title-bar button for full-screen zoom
- MIT license added
- SoundDetective — new ML sound event detection panel (via Tools… menu):
- Apple platforms use the on-device Apple SoundAnalysis neural classifier
- All platforms support loading a user-supplied TFLite model (
.tflite) at runtime; auto-detects matching_labels.txt; configurable model sample rate - Heuristic amplitude-onset fallback when no ML framework or model is available
- Configurable minimum confidence threshold; scrollable event log with timestamp, label, and confidence; auto-trims at 500 events
- Timeline markers — events appear as vertical markers on the log plot
- Clear button resets the event log and the timeline markers simultaneously
- Save Events CSV export
- TFLite cross-platform ML backend — TensorFlow Lite 2.16.2 fetched and linked via CMake on all platforms; defines
SPLMETER_HAS_TFLITE; model input window size adapted automatically from the tensor shape - ViSQOL cross-platform — CMake now detects
Vendor/visqol/lib/visqol_ffi.libon Windows and enables ViSQOL there too; compile definition changed from hard-codedJUCE_MACtoSPLMETER_HAS_VISQOL(with|| JUCE_MACfallback for Xcode builds) - Build fix — AVFoundation and CoreMedia are now explicitly linked in the CMake build, fixing linker errors introduced by SoundDetective's Apple SoundAnalysis backend
- Psychoacoustic Annoyance — real-time Zwicker & Fastl annoyance index (PA) added as a momentary readout in the meter bar and as a selectable trace on the right y-axis of the log plot; included in CSV export
- Specific Loudness — renamed from "Loudness" throughout the UI and CSV output for clarity
- Mel frequency scale — spectrogram now offers a Log / Mel toggle; Mel scale compresses high frequencies and expands low frequencies for perceptually-uniform display
- Save… menu — Save CSV, Save WAV, Save Screenshot, and Save All grouped under a single popup button; Save All exports all three formats in one step to a chosen folder
- Tools… menu — Spectrogram and ViSQOL (macOS) grouped under a single popup button
- ASIO level fix — level readings with ASIO drivers (e.g. 32-channel interfaces) were up to 30 dB too low because the mono mix divided by total hardware channel count; fix counts only channels carrying signal
- Settings… button — renamed from "Settings" for standard macOS/Windows UI convention
- Persistent user settings — all settings (monitor level, FFT parameters, calibration, hold time, bandpass, 94 dB line, light mode, etc.) are saved to disk and restored on the next launch
- Light mode persistence — light/dark theme is remembered across launches
- Correction filter auto-enable — loading a correction curve automatically enables it
- Correction file metadata parsing — if the first line of a correction
.txtcontainsSens FactorandSERNO:(e.g. from a calibrated measurement microphone data sheet), the calibration offset is set to94 + |Sens Factor|and the serial number is filled into the notes field - Windows build provenance — replaced expensive Azure Trusted Signing with free GitHub Artifact Attestations (SLSA); binaries are cryptographically linked to the CI workflow and verifiable with
gh attestation verify - macOS microphone permission — added
NSMicrophoneUsageDescriptionto the app bundle so macOS shows the permission dialog on first launch - Light mode note field — the notes text field now correctly follows the light/dark theme
- Developer ID codesigning — macOS builds are signed with a Developer ID Application certificate and notarized with the Apple Notary Service; Gatekeeper passes without warnings on all Macs
- macOS distribution as DMG — the Standalone app is packaged as a
.dmgso the notarization ticket is preserved through download and the bundle structure is intact - Windows codesigning — Azure Trusted Signing integrated into CI;
.exeand.vst3are signed with a Microsoft-trusted certificate via theazure/trusted-signing-action - Linux support — new CI job builds Standalone + VST3 on Ubuntu; required JUCE system dependencies (ALSA, X11, GL, Freetype, GTK3) resolved via
pkg_check_modules - Persistent Basic / Advanced mode — the app remembers the last used mode across launches; first launch defaults to Basic mode
- ViSQOL integration — perceptual audio quality analysis (MOS-LQO + per-band NSIM) available as a floating panel via the ViSQOL button (Advanced mode only)
- Automatic audio conversion — WAV files are automatically resampled, converted to 16-bit, and mixed to mono before ViSQOL analysis (GPL-compatible, JUCE-only pipeline); conversion details shown in the result panel
- Default window width increased to 1800 px
- Real-time signal flow diagram added to documentation
- Basic / Advanced mode — new mode toggle in the header; app starts in Basic mode (compact SPL meter only); Advanced mode adds the full log plot and psychoacoustic overlay
- 32-channel input — channel count extended from 8 to 32; Settings panel shows 4 rows of 8 per-channel mute buttons (IN01 – IN32)
- Save WAV — records the last Keep Last seconds of IN01 + IN02 as a stereo 24-bit WAV file
- Psychoacoustic axis checkboxes — Roughness, Fluctuation, Sharpness, Loudness now have individual ToggleButton checkboxes on the right y-axis (radio-button behaviour); replaced the old click-on-name selector
- Left / Right y-axis labels — "Left y axis:" and "Right y axis:" section labels added above the respective checkbox rows
- FFT frequency axis — centre-frequency labels (20 Hz – 20 kHz) added along the FFT x-axis
- Settings panel sections — reorganised into four labelled sections: General, FFT, Analysis, Input Channels; thin separator lines between sections
- Calibration, Hold Time, FFT Gain, FFT Smooth — controls changed from rotary knobs to short vertical faders
- Roughness colour — distinct teal colour (was similar to dBA orange)
- Live clock — auto-updating date/time label in the title bar (updates every second)
- Note field — three-line free-text annotation field in the title bar
- Reset button — text colour changed to red (button background unchanged)
- Window width — default width increased to 1500 px; extended height 900 px
- Settings panel — floating settings window replaces individual toolbar controls
- FFT overhaul — band resolution up to 1/24 octave (~240 bands); display modes: Bars, Area, Bars+Peak; window functions: Hann, Hamming, Blackman, Flat-top, Rect; overlap: 0/25/50/75 %; FFT smoothing; peak hold toggle
- RTA +3 dB/oct mode
- Light mode
- Monitor/mute button
- 20-20k Bandpass filter
- Resizable window (default 1400×900)
- SPL series visibility toggles
- Persistent psychoacoustic readout
- Save CSV
- 1/3-octave FFT overlay
- FFT Gain fader
- MIDI learn for Calibration, FFT Gain, Hold Time
- Windows ASIO support
- Initial release
- Broadband SPL measurement in dB, dB(A), dB(C) — peak and RMS
- IEC 61672 FAST / SLOW time weighting
- Horizontal bargraph meter (20–130 dB SPL scale)
- Time-series log plot with configurable history length
- Real-time psychoacoustic metrics
- Real Time and File input modes
- Save JPG export
- Standalone, VST3, and AU formats
MIT License — © 2026 Philipp Paul Klose. See LICENSE for the full text.