Tethered Full-Body Hydraulic Load-Carrying Exoskeleton for Nuclear Decommissioning
| Author | Sheldon K. Salmon (ORCID: 0009-0005-8057-5115) |
| Version | v3.1 (November 14, 2026) |
| License | Creative Commons Attribution 4.0 International (CC BY 4.0) |
| DOI | 10.5281/zenodo.xxxxxxx (replace with your reserved Zenodo DOI) |
Warning
NO HARDWARE EXISTS. This repository contains a concept-level system specification document, not a manufacturing blueprint. Every performance value is a design baseline until physically verified under §13 of the specification. A decided value is not a verified one. This artifact is published as a methodological demonstration of rigorous systems architecture under deep uncertainty, not as evidence of a working system.
- About This Project
- Key Architectural Features
- Repository Structure
- Configuration Checker
- Current Limitations & Open Items
- Citation
- Engagement & Red-Teaming
- Contact
HARDIMAN-X is a conceptual design for a tethered, legged, full-body hydraulic exoskeleton intended for heavy payload handling in nuclear decommissioning environments.
This repository was built in one week using free-tier AI strictly as a computational and literature-retrieval engine, directed by adversarial red-teaming frameworks and strict epistemic discipline. The primary goal is not to deliver a ready-to-build machine, but to demonstrate how to structure complex system logic, manage uncertainty, and design for failure from day one.
The specification is grounded against the historical General Electric Hardiman I final report [GE-71] and the NASA teleoperator survey [NASA-68], while explicitly addressing the documented failure modes of those heritage systems.
This specification distinguishes itself through structural integrity and epistemic honesty:
-
Epistemic Tagging System: Every numerical claim is tagged by its evidence base. This prevents AI hallucinations or unverified assumptions from being treated as facts.
Tag Meaning [D]Directly confirmed [R]Reasoned [S]Structurally inferred [?R]Extrapolated [SPEC]Architectural proposal -
Physics-Gated Configuration (GVWR Rule): The machine uses a Gross Vehicle Weight Rating-style derating rule. Adding option packs mathematically reduces the rated payload one-for-one, preventing feature creep from silently breaking the machine's physical limits.
-
First-Principles Rejections: "Cool but dangerous" concepts (e.g., pyrotechnic egress, joint-level micro-surge accumulators, active kinetic ROPS) are explicitly rejected with first-principles math showing exactly how they would cause catastrophic failure or violate safety allocations.
-
Full Traceability: The document includes a compliance matrix, a parameter register, an assumption map, and a safety-claim register that explicitly lists claims that have not yet been analyzed.
-
Adversarial Fallbacks: Explicit trigger gates define exactly when to abandon the baseline legged design in favor of the tracked variant (TRK).
.
├── HARDIMAN-X_SSD_v3.1.pdf # Compiled, publication-ready specification document
├── HARDIMAN-X_SSD_v3.1.md # Raw Markdown source of the specification
├── hmx_config_check.py # Companion configuration model generator (required by §0)
├── README.md # This file
└── LICENSE # CC BY 4.0 License
hmx_config_check.py
Per §0 Document Conventions of the specification, the configuration model must be re-run after any change to a pack, mass, or position. This script validates the Appendix F tables (Configuration Matrix and Option Packs) and ensures the GVWR derating rules and admissibility checks (CAR-1 to CAR-9) are mathematically sound.
# Ensure you have Python 3.x installed
python3 hmx_config_check.pyThe script outputs a version hash and timestamp, and validates the mass, rating, and offset columns for the defined builds.
Note
The script's version hash and the date of its last run must be published with each release of this specification.
As a concept-level baseline, this document openly acknowledges its evidence gaps (see §15 Open Items and Appendix G):
- Of the 25 source checks in Appendix C.1, 17 are not yet independently verified.
- 30 external evidence requests (EXT-01 to EXT-30) are open for deep search or physical testing.
- The safety-claim register (HMX-10.1-04) holds 4 claims that have not yet been analyzed via FMEA.
- No CAD mass properties or physical hardware-limb test data exist yet (HMX-13.2-09).
The next phase of work is not writing more requirements, but closing these evidence gaps through targeted literature review, supplier data acquisition, and eventual hardware mockup testing.
If you use this specification or its methodology in your research, please cite it as:
Salmon, S. K. (2026). HARDIMAN-X System Specification Document (SSD) v3.1: Tethered Full-Body Hydraulic Load-Carrying Exoskeleton for Nuclear Decommissioning. Zenodo. https://doi.org/10.5281/zenodo.xxxxxxx
This document is designed to invite scrutiny. If you are a systems engineer, robotics architect, or safety analyst, your feedback is highly valued.
How to engage:
- Open an Issue to point out structural failure nodes, undefined terms, or exploitable loopholes in the logic.
- Submit a Pull Request with verified data to close any of the EXT-xx items in Appendix G.
- Critique the epistemic tagging or the GVWR derating mathematics.
Final judgment on load-bearing elements remains with the architect, but adversarial audits are the primary mechanism for improving this specification.
- GitHub: github.com/AionSystem
- ORCID: 0009-0005-8057-5115