Audited phase-tracked regression of periodic helium cryocooler comb artifacts in simultaneous EEG-fMRI.
decomb detects cryocooler harmonics or applies precomputed frozen harmonic models, estimates time-varying shared phase across spatial sensors, executes adaptive leave-one-cycle-out (LOCO) harmonic regression, writes standard EEG-BIDS derivatives, verifies sample-level numerical exactness via deterministic replay, and generates comprehensive diagnostic figures and provenance manifests.
| Feature | Specification |
|---|---|
| Target Artifact | Quasi-periodic helium compressor pump comb ( |
| Frequency Scope | Comb harmonics from 10 to 110+ Hz (configurable across acquisition bandwidth) |
| Phase Engine | Circular consensus with Huber robust weighting ( |
| Fitting Engine | Adaptive leave-one-cycle-out (LOCO) regression with Gaussian weighting ( |
| Input Format | Continuous BrainVision EEG recordings structured as EEG-BIDS datasets |
| Verification Gate | Deterministic sample-exact replay confirming zero maximum absolute deviation |
flowchart LR
A["Raw EEG-BIDS"] --> B["Harmonic Selection"]
B --> C["Shared Phase Tracking"]
C --> D["Adaptive LOCO Regression"]
D --> E["BIDS Derivative"]
E --> F["Replay Verification"]
E --> G["Diagnostic Reports"]
- Harmonic Selection: Discovers prominent comb teeth via Welch power spectral density or loads a precomputed frozen harmonic manifest.
- Shared Phase Tracking: Decomposes overlapping Hann windows into spatial singular vectors, combining phase evidence across harmonics using Huber robust circular consensus.
- Adaptive LOCO Regression: Segments continuous data into cycles, fitting harmonic coefficients with local Gaussian weighting while excluding the predicted cycle to prevent overfitting.
- BIDS Derivative: Writes verified BrainVision float32 derivatives alongside cryptographic provenance manifests.
- Replay Verification: Replays the recorded regression against untouched source data to verify bitwise numerical exactness.
- Diagnostic Reporting: Outputs publication-ready spectral summaries, scalp topographies, and synthetic probe recovery benchmarks.
Python 3.11 or newer is required.
python3 -m venv .venv
source .venv/bin/activate
pip install -e .Create a configuration file decomb.yaml pointing to your EEG-BIDS dataset:
paths:
bids_root: /path/to/bids-datasetExecute the end-to-end pipeline (correction, verification, and diagnostic plots):
decomb run --config decomb.yamlBy default, the corrected derivative is written to <bids_root>_cryocoolerregressed and reports are saved to <bids_root>_decomb_reports/removal. Existing output directories are strictly rejected to prevent accidental overwriting.
decomb provides modular commands for execution, testing, and inspection:
| Command | Primary Action | Typical Output |
|---|---|---|
decomb run --config decomb.yaml |
Complete sequential workflow (apply verify psd) |
Corrected dataset, verification table, figures |
decomb apply --config decomb.yaml |
Estimates phase, regresses harmonics, writes BIDS derivative |
sub-*/[ses-*/]eeg/*_eeg.vhdr, manifest.json
|
decomb verify --config decomb.yaml |
Deterministic replay from source data |
verification_summary.tsv (exact parity check) |
decomb psd --config decomb.yaml |
Computes Welch spectra and generates diagnostic plots | Diagnostic PNG/PDF figures, spectral caches |
run, apply, and verify process the complete dataset to guarantee dataset-level provenance integrity. psd can inspect specific participants via --subjects 01 02.
decomb supports two complementary selection workflows:
-
Automatic Detection (default /
--detect): Discovers prominent comb harmonics directly from each recording's Welch power spectrum (prominence$> 0.5\text{ dB}$ , width$\le 4$ bins). This mode is self-contained and conservative. -
Frozen Model (
--model <path>orpaths.model_manifest): Applies fixed harmonic sets defined in advance via a TSV/JSON manifest. A frozen model captures weaker teeth that fall below single-recording detection thresholds across a cohort.
# Automatic detection (default)
decomb run --config decomb.yaml --detect
# Precomputed frozen harmonic model
decomb run --config decomb.yaml --model /path/to/harmonics.tsvBoth modes execute the identical regression engine and produce the same provenance metadata replayed by verify. In a 126-recording cohort benchmark, the frozen set averaged 65.5 teeth per recording and automatic detection averaged 47.9 teeth, agreeing within 0.04 dB on harmonics selected by both methods. For format specifications, see frozen models; for empirical measurements, see the mode comparison.
All pipeline parameters can be configured in decomb.yaml. Relative paths resolve from the current working directory:
paths:
bids_root: /path/to/bids-dataset # Source EEG-BIDS root
output_root: /path/to/corrected-dataset # Corrected derivative root (optional)
removal_dir: /path/to/reports # Diagnostic reports and figures (optional)
task: rest # Target task name, or "*" for all tasks
# model_manifest: /path/to/harmonics.tsv # Optional precomputed frozen harmonic model
removal:
comb_fundamental_hz: 1.2 # Declared hardware fundamental frequency (Hz)
anchor_harmonics: [43, 45, 49, 51] # Mandatory harmonics contributing to shared phase
phase_tracking_window_s: 20.0 # Hann window duration for phase SVD (s)
regression_window_count: 3 # Number of phase windows per support block (60 s total)
phase_hop_s: 1.0 # Temporal step between phase updates (s)
phase_robust_cutoff_rad: 0.7 # Huber robust loss threshold (radians)
local_coefficient_sigma_s: 20.0 # Gaussian weighting scale for LOCO coefficients (s)
estimation_window_s: 10.0 # Welch window duration for harmonic screening (s)The default configuration describes a 1.20 Hz cryocooler comb (72 cycles/min). The fundamental frequency is an explicit hardware parameter, not inferred from data. All selected teeth at or above the lowest anchor contribute to the shared phase estimate.
decomb provides programmatic access to its core regression engine for integration into custom scientific pipelines:
import mne
from decomb.cryocooler import CryocoolerRegressionSettings, regress_cryocooler
# Load continuous EEG data
raw = mne.io.read_raw_brainvision("sub-01_task-rest_eeg.vhdr", preload=True)
picks = mne.pick_types(raw.info, eeg=True, exclude="bads")
eeg_data = raw.get_data(picks=picks)
sampling_rate = raw.info["sfreq"]
# Define regression geometry and harmonic parameters
settings = CryocoolerRegressionSettings(
fundamental_hz=1.2,
harmonic_numbers=(8, 18, 43, 45, 49, 51),
anchor_harmonic_numbers=(43, 45, 49, 51),
segment_duration_s=20.0,
regression_window_count=3,
phase_hop_s=1.0,
phase_robust_cutoff_rad=0.7,
local_coefficient_sigma_s=20.0,
)
# Execute audited regression
result = regress_cryocooler(eeg_data, sampling_rate, settings)
# Access cleaned data, artifact estimate, and continuous phase trajectory
cleaned_eeg = result.cleaned_data # ndarray of shape (n_channels, n_samples)
artifact_comb = result.artifact_data # ndarray of shape (n_channels, n_samples)
tracked_phase = result.phase_radians # ndarray of shape (n_samples,)Every complete pipeline run produces publication-ready summaries and signal-preservation benchmarks derived directly from the dataset:
Harmonic suppression across the frequency spectrum, detailed reduction indices on focused teeth, and a scalp map of comb prominence. Each tooth's reduction uses only recordings that modeled it; error bars represent sample standard deviations across recordings. The scalp map is projected from recorded sensor coordinates:
Paired spectral change (
See figure conventions for averaging definitions, uncertainty representations, and interpretation guidelines.
Alongside visual figures, each run generates structured provenance and validation tables:
- Harmonic measurements table (
harmonic_measurements.tsv): Recording-level suppression and baseline power per tooth. - Verification summary (
verification_summary.tsv): Bitwise maximum sample deviations from deterministic replay. - Cryptographic provenance manifest (
manifest.json): Schema-4 record containing algorithm digests, runtime parameters, and input file hashes. - Panel availability log (
plot_availability.json): Explicit records of any omitted figures (e.g., absent sensor coordinates) to prevent silent fallback or approximation.
Inputs must be continuous BrainVision EEG recordings structured as EEG-BIDS datasets. Reading uses MNE-BIDS; array computation uses MNE-Python, NumPy, and SciPy. Missing inputs, invalid models, and unsupported acquisition geometries raise immediate errors.
- Target Scope:
decombspecifically targets the periodic narrowband helium cryocooler comb artifact in continuous EEG. - Data Integrity: Source recordings are treated as strictly immutable. Bad EEG channels, auxiliary non-EEG channels (ECG, EOG), annotations, and sampling intervals are preserved without modification.
- Regression Engine (
robust_shared_phase_adaptive_loco_v1):- Robust shared phase is computed from overlapping 20-second Hann windows updated every second. Harmonics at or above the lowest anchor are spatially pooled via SVD, then combined using circular consensus with Huber robust weights (0.7-radian cutoff).
- Coefficients are estimated within 60-second support blocks using adaptive leave-one-cycle-out (LOCO) regression with a 20-second Gaussian kernel and SNR shrinkage.
- Automatic and frozen selection modes execute this identical engine.
- Verification and Reproducibility: Every run writes a Schema-4 model manifest recording all method parameters and cryptographic digests.
decomb verifyreplays the recorded regression sample-for-sample to confirm exact numerical reproduction. - Scientific Boundaries: Neural activity coherent with the cryocooler cannot be distinguished from the artifact by spectral regression alone. Synthetic probe recovery evaluates filter transparency, not unobserved endogenous neural dynamics. See methods and limitations.
decomb/
├── src/decomb/ # Core library: phase tracking, LOCO regression, BIDS I/O, verification
│ ├── cli.py # Command-line interface entry points
│ ├── cryocooler.py # Core regression engine and settings
│ ├── shared_phase.py # SVD and Huber robust consensus phase estimator
│ ├── defaults.yaml # Baseline acquisition and algorithm configuration
│ └── figures/ # Publication-grade plotting modules
├── docs/ # Documentation: methods, models, plotting, references
│ ├── README.md # Documentation index and study records
│ ├── methods.md # Mathematical formulations, data boundary, limitations
│ ├── frozen-models.md # Schema-4 frozen model specifications and export
│ ├── plotting.md # Diagnostic figures, metric definitions, caching
│ ├── tuning.md # Cold-head phase tracking window tuning guide
│ └── references.md # Literature citations and software reference index
├── studies/cryocooler_2026/ # 2026 validation study: cohort models, assessments, reports
│ └── README.md # Study workflow and module map
├── experiments/ # Exploratory studies outside production API (e.g., ventilation fans)
│ └── README.md # Non-production investigation index
├── tests/ # Test suite: unit verification, pipeline integration, regressions
├── CITATION.cff # Machine-readable software citation metadata
├── CONTRIBUTING.md # Development workflows and verification commands
└── LICENSE # BSD 3-Clause License
For study workflows and module maps, see the 2026 cryocooler study. For development commands, see contributing.
Until an archival DOI is assigned, cite the exact software release used in the analysis:
Duquette, J. (2026). decomb (version 0.5.0) [Computer software]. https://github.com/JoshuaDuq/decomb
@misc{duquette_decomb_2026,
author = {Duquette, Joshua},
title = {decomb},
year = {2026},
version = {0.5.0},
url = {https://github.com/JoshuaDuq/decomb},
note = {Computer software}
}Canonical metadata is maintained in CITATION.cff. When referring to underlying methodologies or software libraries, cite the primary literature indexed in docs/references.md.
BSD 3-Clause License; see LICENSE.