@euyniy

@euyniy euyniy commented Nov 5, 2026

Copy link
Copy Markdown
Contributor

Prevent irrelevant shakiness

@euyniy
euyniy requested review from stevenaya and tokirobot November 5, 2026 02:54
@kou

kou commented Nov 9, 2026

Copy link
Copy Markdown
Contributor

How about using the timestamp field instead of seq to compute the sample time?

I checked the firmware, and seq counts sent frames, not acquired samples:

  • acquisitionTask stamps each sample with micros() (main.cpp#L139) and writes it into a 1-deep queue with xQueueOverwrite() (L252, L428).
  • streamTask increments seq only for frames it actually sends (L488).

So when streamTask falls behind and a sample gets overwritten, time passes but seq doesn't advance. seq × period then underestimates dt. The 1 kHz period is also an assumption: the acquisition loop runs at roughly 1 kHz (vTaskDelay(1) plus processing time), not exactly.

The firmware already sends the acquisition time as timestamp (uint32 µs from micros()) in every frame (L385). Using it would:

  • give the real dt even when samples are overwritten before sending,
  • make --ker-rate-hz unnecessary.

The change is small. The wraparound and restart handling can stay as it is:

class SampleClock:
    """Sample time in seconds from the device "timestamp" field (micros())."""

    def __init__(self):
        self.timestamp_prev = None
        self.t = 0.0

    def update(self, timestamp_us: int) -> tuple[float, bool]:
        if self.timestamp_prev is None:
            self.timestamp_prev = timestamp_us
            return self.t, False

        # micros() is uint32 and wraps about every 71.6 minutes.
        gap = (timestamp_us - self.timestamp_prev) & 0xFFFFFFFF
        self.timestamp_prev = timestamp_us
        # A huge gap is the timestamp going back (device restart).
        if gap >= 1 << 31:
            return self.t, True

        self.t += gap * 1e-6
        return self.t, False
-            if one_euro is not None and "seq" in data:
-                t, restarted = clock.update(data["seq"])
+            if one_euro is not None and "timestamp" in data:
+                t, restarted = clock.update(data["timestamp"])

What do you think?

seq counts frames the firmware sends, not samples it acquires: when
streamTask falls behind and xQueueOverwrite() drops a sample, time
passes but seq does not advance, so seq * period underestimates dt.
The 1 kHz rate is also only nominal.

The firmware stamps every sample with micros() at acquisition and
sends it as "timestamp", so use that instead. This drops the
--ker-rate-hz option. Wraparound and restart handling stay the same.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@euyniy

euyniy commented Nov 9, 2026

Copy link
Copy Markdown
Contributor Author

@kou I made some change to the timestamp detection. What do you think?

@kou
kou merged commit 5635d31 into enactic:main Nov 10, 2026
4 checks passed