openarm base_link center of mass: x and z signs differ from openarm_description #107
While generating a MuJoCo model of OpenArm 2.0 from openarm_description for our mobile platform, we compared it with openarm_mujoco (commit 1daab06). Kinematics, masses and inertias match. One difference: openarm_description gives the arm base_link center of mass at x +2.53 mm and z +0.03 mm in the base frame, while openarm_mujoco has the opposite signs for x and z.
It does not affect arm dynamics on a fixed base, but it matters on a moving base. Could you confirm which one is correct?
Also for reference: friction.yaml in openarm_description is empty at the current pin. If you have measured joint friction or rotor inertia for the 2.0 motors, we would gladly use them.
This was an old bug. The installation of the base link between the cell and the pedestal was different. The base link should be rotated 180 degrees in the pedestal version XML. But we kept it the same as the cell version for convenience. I have been working on that since last week and have already prepared some PRs (#105 ).
The base_link COM sign mismatch has been fixed in #105, which is now merged into master. The standard V2 bimanual/pedestal model now uses x = +0.00253124 m and z = +0.0000270658 m, with the inertia orientation updated consistently. The previous values came from applying the Cell-specific 180-degree Y-axis mounting rotation to the standard assembly as well.
The Cell variant intentionally retains that rotated mounting and the corresponding negative X/Z COM coordinates. Please use the standard assembly for the unrotated base installation.
This resolves the reported COM mismatch; measured joint friction and rotor inertia are separate from this fix. Thank you for reporting it!
Activity
stevenaya commentedon Nov 16, 2026
This was an old bug. The installation of the base link between the cell and the pedestal was different. The base link should be rotated 180 degrees in the pedestal version XML. But we kept it the same as the cell version for convenience. I have been working on that since last week and have already prepared some PRs (#105 ).
stevenaya commentedon Nov 20, 2026
The base_link COM sign mismatch has been fixed in #105, which is now merged into master. The standard V2 bimanual/pedestal model now uses x = +0.00253124 m and z = +0.0000270658 m, with the inertia orientation updated consistently. The previous values came from applying the Cell-specific 180-degree Y-axis mounting rotation to the standard assembly as well.
The Cell variant intentionally retains that rotated mounting and the corresponding negative X/Z COM coordinates. Please use the standard assembly for the unrotated base installation.
This resolves the reported COM mismatch; measured joint friction and rotor inertia are separate from this fix. Thank you for reporting it!
BotshareAI commentedon Nov 20, 2026
Thank you! @stevenaya