Skip to content

About

Sensing P2 BLDC Motor platform vibration with Peizo and 6DOF sensors

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Latest commit

 

History

5 Commits

Folders and files

NameName
Last commit message
Last commit date
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

P2-VibrationSense

Sensing the vibration of a Propeller 2 (P2) BLDC motor platform with a piezo sensor and a 6-degrees-of-freedom (6DOF) IMU.

The project provides two independent Spin2 driver objects, one per sensor. Each captures a burst of timestamped samples into a buffer you supply, so you can analyze the vibration afterward. A demo program uses both to report:

  • Piezo sensor: the vibration's frequency. The piezo gives no direction.
  • 6DOF IMU: the vibration's size (in g) and frequency along each of X, Y and Z.

Status: early development. Both capture objects and the demo work on hardware: the IMU at 1.66 kHz and the piezo at 2 kHz with no missed samples, and the demo reports levels, frequencies and a timeline from an 8 s capture. The interface may still change.

The two driver objects

Both objects work the same way:

  1. Start the object. It launches its own cog and sets up the sensor.
  2. Capture. The cog samples the sensor at a steady rate. It stores each sample with its CT clock offset (P2 system-clock ticks since the first sample of the capture) into your buffer.
  3. Stop. Capture ends when you stop it or when the buffer is full.
  4. Read the samples back and process them. Nothing is analyzed during capture, so the sampling cog does nothing but sample.

Because each sample carries its own timestamp, you can check the actual sample spacing and jitter, not just assume the nominal rate.

Common interface

Both objects share these calls, and can be called from any cog:

Call What it does
start(...) : ok Launch the capture cog, set up the sensor, return once ready (parameters differ; see below)
startCapture(pBuf, maxSamples) : ok Begin filling your buffer; stops by itself when full
stopCapture() End a capture early
isCapturing() : bool True while samples are being written
sampleCount() : n Samples written in the current or last capture
actualRateHz() : hz The rate in use (nominal for the IMU; exact for the piezo)
getSample(i) : ctOffset, value(s) One sample: clocks since the first sample, then the value(s)
stop() Release the sensor, pins and cog

Differences:

Piezo (isp_piezo_capture) IMU (isp_imu_capture)
start start(pin, sampleRateHz) start(clickBasePin, sampleRateHz, accelFullScale, withGyro)
getSample(i) returns ctOffset, microvolts ctOffset, ax, ay, az (raw counts)
Bytes per sample SAMPLE_BYTES (8) SAMPLE_BYTES_ACCEL (10) or SAMPLE_BYTES_ACCEL_GYRO (16); sampleBytes()
Extras recalibrate(), calibration(), samplePeriodClocks() getGyro(i), accelMicroG(raw), gyroMicroDps(raw), ACCEL_FS_*

Piezo capture object

  • Sensor: an amplified piezo vibration sensor, analog output.
  • Connection: signal on P0, powered from the 3.3 V and GND of the P0–P7 header.
  • Object: src/isp_piezo_capture.spin2.
  • How it samples: P0 runs as a P2 ADC smart pin taking a reading every 8,192 clocks (24.4 kHz at 200 MHz). The capture cog averages N readings into each stored sample, so the rate is exactly clkfreq / (8192 × N); for example, 2,034.5 Hz for N = 12. The averaging also filters out higher frequencies.
  • Calibration: the object reads its pin group's own ground (P_ADC_GIO) and 3.3 V (P_ADC_VIO) and scales pin readings between them, so supply and temperature drift cancel out. The piezo's output needs several ms to recover after the ADC switches back to the pin, so calibration only happens while idle (at start() or recalibrate()), followed by a 50 ms settle.
  • Sample value: one reading per sample, in microvolts.

Usage:

OBJ
  piezo : "isp_piezo_capture"

VAR
  byte  buf[2048 * piezo.SAMPLE_BYTES]

PUB main() | i, ct, uv
  piezo.start(0, 2000)                                          ' pin, rate (-> 2,034.5 Hz)
  piezo.startCapture(@buf, 2048)
  repeat while piezo.isCapturing()
  repeat i from 0 to piezo.sampleCount() - 1
    ct, uv := piezo.getSample(i)                                ' ct: clocks since first sample
  piezo.stop()

IMU capture object

  • Sensor: MikroElektronika LSM6DSL Click, MIKROE-2731 (ST LSM6DSL 3-axis accelerometer + 3-axis gyroscope).
  • Connection: a Parallax P2-to-mikroBUS Click Adapter (#64008) on pin group P32–P47, talking SPI (CS P40, SCK P41, MISO P42, MOSI P43). The sensor's data-ready interrupt is on P36.
  • How it samples: the capture cog waits for data-ready, reads the timestamp, then burst-reads all six axes. Accelerometer sample rates go up to 6.66 kHz.
  • Sample value: accelerometer X, Y and Z per sample (gyro X, Y and Z optional).

Usage:

OBJ
  imu : "isp_imu_capture"

VAR
  byte  buf[1660 * imu.SAMPLE_BYTES_ACCEL]                     ' ~1 s at 1.66 kHz, accel only

PUB main() | i, ct, ax, ay, az
  imu.start(32, 1660, imu.ACCEL_FS_8G, false)                  ' base pin, rate, range, gyro?
  imu.startCapture(@buf, 1660)
  repeat while imu.isCapturing()
  repeat i from 0 to imu.sampleCount() - 1
    ct, ax, ay, az := imu.getSample(i)                         ' ct: clocks since first sample
    ' imu.accelMicroG(ax) converts counts to micro-g
  imu.stop()

The rate you ask for is rounded up to the next rate the LSM6DSL supports (actualRateHz()). The chip's real rate differs from nominal by several percent, so compute the rate from the ct offsets for any frequency analysis. With the gyro on, use imu.SAMPLE_BYTES_ACCEL_GYRO per sample and read it with getGyro(i).

It's built in layers. You'd normally use only the capture object.

Layer File Role
IMU capture object src/isp_imu_capture.spin2 Capture cog, timestamps, buffer
LSM6DSL driver src/isp_lsm6dsl.spin2 Chip registers: setup, rate and range, data-ready, burst reads, unit conversion
SPI src/isp_spi.spin2 SPI on P2 smart pins, selectable mode 0–3; the LSM6DSL uses mode 3

isp_spi.spin2 is derived from Jon McPhalen's jm_ez_spi.spin2 (mode 0 only), which stays in src/ as the reference.

Note: the SPI and LSM6DSL layers drive pins from whichever cog calls them. Make every call to them from one cog; in the finished design that's the capture cog.

Hardware

P2 pins Device
P0 Amplified piezo vibration sensor
P32–P47 LSM6DSL Click in a P2-to-mikroBUS Click Adapter

Full pinout, jumper settings and power notes: HARDWARE.md.

Building and running

The code is Spin2 for the P2 and builds with PNut-TS:

cd src
pnut-ts -d vibration_demo.spin2
pnut-term-ts --headless -r vibration_demo.bin --end-marker --timeout 120

The demo

vibration_demo.spin2 starts both capture objects, captures 8 s (thump or shake the platform during it), and prints a report:

  • Level and vibration size per channel (piezo, accel X/Y/Z): resting level, RMS, peak swing and when it happened, with a warning if the accelerometer clipped.
  • Strongest frequencies: the top 3 frequencies and amplitudes in the most active ~2 s of each channel.
  • Dominant frequency over time: per ~0.5 s segment, the dominant frequency and its amplitude, or "quiet".

Frequencies are computed from each sensor's measured sample rate. The analysis uses src/isp_fft.spin2, a Spin2 FFT object with a Hann window and between-bin refinement of frequency and amplitude.

Test programs in src/

Program What it checks
lsm6dsl_test.spin2 Bring-up: SPI mode probe, chip ID (WHO_AM_I = $6A), ten accel/gyro samples, temperature
imu_capture_test.spin2 1 s captures at 1.66 kHz, accel-only then accel + gyro: measured rate, sample-interval jitter, missed samples, per-axis mean / RMS / peak
piezo_test.spin2 Piezo bring-up: GIO/VIO calibration, resting level and noise, and the pin's recovery after a source switch
piezo_thump_test.spin2 Waits up to 30 s for a desk thump, captures 1 s at 24.4 kHz: peak swing, decay per 50 ms, frequency estimate
piezo_capture_test.spin2 ~1 s capture at 2 kHz: measured rate, sample-interval jitter, missed samples, level and noise
fft_test.spin2 isp_fft on synthetic tones (50 Hz and 123.4 Hz plus a DC offset): found frequencies and amplitudes, and analysis time for 1,024 / 2,048 / 4,096 points

Documentation

License

MIT; see LICENSE. jm_ez_spi.spin2, and the parts of isp_spi.spin2 derived from it, are © Jon McPhalen, also MIT.

About

Sensing P2 BLDC Motor platform vibration with Peizo and 6DOF sensors

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Releases

Sponsor this project

Contributors