Skip to content
planetf1Public

About

CLI + TUI manager for XikeStor SKS3200-8E2X switches

Topics

Resources

Stars

11 stars

Watchers

2 watching

Forks

Repository files navigation

sks3200 — XikeStor SKS3200-8E2X Switch Manager

A Rust CLI + TUI tool for managing XikeStor (兮克) SKS3200-8E2X switches remotely. These are 8×2.5G + 2×10G SFP+ web-managed switches with a basic HTML dashboard — no CLI, no SSH, no SNMP.

Tested with firmware 2.0.0.3. Other firmware versions may have different API behaviour, especially write endpoints.

Read-write Switch Management. Query system info, port status, traffic statistics, MAC tables, VLANs, STP, loop protection, and more — plus configure ports, VLANs, IGMP, storm control, mirroring, trunk/LACP, loop protection, STP, network settings, description, and manage config backups. Use --dry-run to preview changes without applying them, or --mock for local offline testing.


Quick start

# Generate a config file template and edit it
sks3200 config-init > ~/.config/sks3200/config.toml
# Then edit ~/.config/sks3200/config.toml with your switch credentials

# Once configured, query all switches at once
sks3200 show status

# Port status
sks3200 show ports

# Traffic statistics (live refresh with rates)
sks3200 show statistics --watch --interval 5

# Live TUI Dashboard (monitoring with dark/light theme, sparklines, config editor)
sks3200 monitor --interval 10

# MAC address table
sks3200 show mac

# Everything at once
sks3200 show all

# JSON output for scripting
sks3200 -j show status | jq '.temperature'

Example output

All commands produce colour-coded, aligned tables with live data.

sks3200 show status

═══ main (192.168.100.7) ═══
╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌
 SKS3200-8E2X  SKS3200-8E2X
╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌
  Firmware:           2.0.0.3
  Hardware:           A0
  MAC Address:        AA:BB:CC:DD:EE:FF
  IP Address:         192.168.100.7
  Temperature:        52°C
  Netmask:            255.255.255.0
  Gateway:            192.168.100.254
  DNS:                8.8.8.8
  DHCP:               Static

sks3200 show ports

═══ main (192.168.100.7) ═══
 PORT SETTINGS  Mode: PORT_MODE_8_PLUS_2  Active: 6/10
╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌
 Port    Status     Actual Speed         Config               Flow Ctrl    EEE
──────────────────────────────────────────────────────────────────────────────────────────
 Port 1  Enabled    Link Down            Auto                 On           Inactive
 Port 2  Enabled    2500MbpsFull         Auto                 On           Inactive
 Port 3  Enabled    100MbpsFull          Auto                 Off          Inactive
 Port 4  Enabled    1000MbpsFull         Auto                 On           Inactive
 Port 5  Enabled    Link Down            Auto                 On           Inactive
 Port 6  Enabled    1000MbpsFull         Auto                 On           Active
 Port 7  Enabled    100MbpsFull          Auto                 On           Inactive
 Port 8  Enabled    2500MbpsFull         Auto                 On           Active
 Port 9  Enabled    Link Down            Auto                 Off          N/A
 Port 10 Enabled    Link Down            Auto                 Off          N/A

sks3200 show statistics

═══ main (192.168.100.7) ═══
 PORT STATISTICS
╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌
 Port    Status           Tx Good          Tx Bad           Rx Good          Rx Bad
────────────────────────────────────────────────────────────────────────────────────────────────────
 Port 1  Link Down        0                0                0                0
 Port 2  2500MbpsFull     80.4M            0                25.2M            5
 Port 3  100MbpsFull      4.2M             0                737.5K           0
 Port 4  1000MbpsFull     143.8M           0                9.9M             0
 Port 5  Link Down        0                0                0                0
 Port 6  1000MbpsFull     3.7M             0                86.2K            11.8K
 Port 7  100MbpsFull      4.0M             0                1.2M             0
 Port 8  2500MbpsFull     54.5M            0                221.4M           0
 Port 9  Link Down        0                0                0                0
 Port 10 Link Down        0                0                0                0

Add --watch (with optional -i, --interval <sec>) for a live-updating view with real-time per-second packet rate deltas (Tx/s, Rx/s). The interval defaults to 5 s and is clamped to a minimum of 3 s: faster polling has frozen the switch's embedded web server on real hardware.

sks3200 show mac

═══ main (192.168.100.7) ═══
 DYNAMIC MAC TABLE  37 entries
╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌
 #   MAC Address            VLAN   Port   Age
──────────────────────────────────────────────────────────────────────────────────────────
 1   00:1A:2B:3C:4D:01      1      8      225   s
 2   00:1A:2B:3C:4D:02      1      6      300   s
 3   00:1A:2B:3C:4D:03      1      8      300   s
 4   00:1A:2B:3C:4D:04      1      8      188   s
 5   00:1A:2B:3C:4D:05      1      2      300   s
 6   00:1A:2B:3C:4D:06      1      8      281   s
 ...
 37  AA:BB:CC:DD:EE:FF      1      0      225   s     ← the switch itself

sks3200 show vlan

═══ main (192.168.100.7) ═══
 PORT VLAN CONFIGURATION
╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌
 Port    PVID     Frame Type
──────────────────────────────────────────────────
 Port 1  1        All
 Port 2  1        All
 Port 3  1        All
 Port 4  1        All
 Port 5  1        All
 Port 6  1        All
 Port 7  1        All
 Port 8  1        All
 Port 9  1        All
 Port 10 1        All

sks3200 show stp

═══ main (192.168.100.7) ═══
 SPANNING TREE  Mode: RSTP  (Disabled)
╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌╌
 Port    Status       Edge     Path
────────────────────────────────────────────────────────────
 Port 1  Disabled     No       ─
 Port 2  Disabled     No       ─
 Port 3  Disabled     No       ─
 Port 4  Disabled     No       ─
 Port 5  Disabled     No       ─
 Port 6  Disabled     No       ─
 Port 7  Disabled     No       ─
 Port 8  Disabled     No       ─
 Port 9  Disabled     No       ─
 Port 10 Disabled     No       ─

sks3200 show all

Runs all supported commands in sequence and prints every section — useful for a quick full inventory of a switch. Output combines status, ports, statistics, mac, vlan, network, loop, and stp sections.

TUI dashboard (sks3200 monitor)

A ratatui-based real-time dashboard with auto-refresh.

┌─────────── Header ─────────────────────────────────────────────────────┐
│ SKS3200-8E2X @ 192.168.100.7  FW: 2.0.0.3  HW: A0  52°C  Up: 4/10    │
├─────────────── Ports (4 up) ────────────┬─────── MAC Table (37) ───────┤
│ Port Status Speed  Tx/s    Rx/s  TxErr  │ MAC Address         VLAN Port│
│ P1   Up     2.5G  123.4K  45.6K    0   │ AA:BB:CC:DD:EE:01    1    2 │
│ P2   Up     1G      890   1.2K    12   │ AA:BB:CC:DD:EE:02    1    8 │
│ ...                                    │ ...                         │
│ P8   Up     2.5G   54.5M 221.4M     0   │ AA:BB:CC:DD:EE:FF    1    0 │
│ Σ            123.4M   46.8M     12     │ churn: 3                     │
├─── Sparklines ─────────────────────────┴──────────────────────────────┤
│ P1  123.4K/ 45.6K  ▁▂▃▅▇█▆▄▂▁▁▂▃▄▅▆▇█▇▆▅▄▃▂▁                         │
│ P2    890/  1.2K   ▁▁▂▃▄▅▆▇█▇▆▅▄▃▂▂▁▁▂▃▄▅▆▇█                         │
│ P4  143.8M/  9.9M  ▁▂▂▃▃▄▅▅▆▇█▇▆▆▅▄▃▂▁▁▂▂▃▄▅▆▇██                     │
├──────────────── Footer ────────────────────────────────────────────────┤
│ [q] Quit  [r] Refresh  [+/-] 3s  [←→] main  Pane: Ports  Last: 08:34 │
└────────────────────────────────────────────────────────────────────────┘

The port table now includes error rate columns (TxErr/s, RxErr/s) with colour-coded error ratio (Err%): green <0.1%, yellow 0.1–1%, red >1%. The aggregate Σ row sums throughput across all ports.

Sparklines show 60-point traffic history per active port (bar-chart trend over 10 minutes at the default 10 s refresh, 3 minutes at the 3 s minimum).

MAC churn (title counter) tracks how many entries appeared or disappeared between refreshes. The header shows the active port count (Up: N/10).

Run it:

sks3200 -s 192.168.100.7 monitor

Keys: q to quit, r to refresh now, t to toggle the dark/light theme, Tab to cycle panes (Ports → MAC → Config), ←/→ to switch between configured switches, +/- to adjust the refresh rate (3–60 s, default 10 s), arrows to scroll, Enter to edit a field in the Config pane.

The theme paints its own background, so text stays readable whatever your terminal's colour scheme. The initial theme follows COLORFGBG where the terminal sets it, and defaults to dark otherwise.

Gentle polling. The switch's embedded web server is fragile, so the dashboard keeps its request load low:

  • Port statistics are fetched every refresh; system info and port settings every 60 s; the dynamic MAC table (a full hardware table dump on the switch) at most every 30 s; Config pane data only while that pane is open.
  • One keep-alive HTTP connection is reused across refreshes.
  • Pane and switch changes refresh at most once a second, so holding a key cannot flood the switch.
  • If a request times out or cannot connect, the rest of that refresh is skipped. After two refreshes in which the switch did not answer at all, the dashboard sends a single probe request per refresh until it responds.

Commands

Read Commands (show)

Command Description
show status System information (temperature, IP, MAC, firmware)
show ports Port status and settings
show statistics Port traffic statistics (add --watch for live refresh)
show mac Dynamic MAC address table
show static-mac Static MAC address table
show trunk Link aggregation / trunk status
show vlan VLAN configuration
show stp Spanning Tree Protocol status
show loop Loop protection status
show igmp IGMP snooping configuration
show storm Storm control configuration
show mirror Port mirror configuration
show network Network settings (IP, gateway, DNS)
show all Show all information at once

Write Commands (set)

Command Description
set port Configure port (status, speed, flow control)
set description Set device description
set vlan Configure VLAN per-port (PVID, frame type)
set igmp Configure IGMP snooping
set network Update IPv4 network settings
set storm Configure storm control rates
set stp Enable/disable Spanning Tree Protocol
set mirror Configure port mirroring
set trunk Configure trunk/LACP per-port
set loop-protection Configure loop protection

Management Commands

Command Description
clear statistics Clear port statistics counters
clear mac Clear dynamic MAC address table
save Save running config to startup
backup Backup configuration to JSON file
restore Restore configuration from backup
reboot Reboot the switch (requires --yes --apply)
factory-reset Factory reset (requires --yes --apply)
monitor TUI dashboard (live monitoring)
config-init Generate a sample config file template
help Print help for a given subcommand

Write Commands — Safety Model

Write commands (set, clear, save, restore) apply to the real switch by default. Use flags to control behaviour:

# Real switch (default): applies the change
sks3200 set port 1 --speed 1000 --flow off

# Dry run: shows what would be sent without applying
sks3200 set port 1 --speed 1000 --flow off --dry-run

# Mock mode: safe sandbox, no real switch affected
sks3200 --mock set port 1 --speed 1000 --flow off

Destructive commands (reboot, factory-reset, restore) require --yes to confirm on a real switch:

sks3200 reboot --yes
sks3200 factory-reset --yes

Options

Flag Env Default Description
-s, --switch SKS3200_HOST — (all configured) Switch names/IPs (comma-separated)
-c, --config — ~/.config/sks3200/config.toml Path to config file
-u, --user SKS3200_USER admin Login username
-p, --password SKS3200_PASSWORD — Login password
-j, --json — — Output raw JSON

Multi-switch

Configure multiple switches in ~/.config/sks3200/config.toml (generate a template with sks3200 config-init). Commands query all configured switches by default, with a ═══ name (host) ═══ header between them.

[[switch]]
name = "main"
host = "192.168.100.7"
password = "changeme"

[[switch]]
name = "secondary"
host = "192.168.100.8"
password = "changeme"

Target specific switches with -s:

sks3200 -s main status
sks3200 -s secondary ports
sks3200 -s 192.168.100.7 -- all   # ad-hoc (not in config)

Installation

From source:

cargo install --path .

From source with TUI dashboard:

cargo install --features tui --path .

Via Homebrew (macOS / Linux):

brew install planetf1/tap/sks3200

Via installer script (any platform):

curl --proto '=https' --tlsv1.2 -LsSf https://github.com/planetf1/sks32kmon/releases/latest/download/sks3200-installer.sh | sh

Binaries are published for Apple Silicon, Intel Mac, ARM64 Linux, and x86_64 Linux on the GitHub Releases page.

Security

  • Credentials are transmitted as MD5 hashes (plaintext-equivalent on the wire).
  • Session cookies use http-only over plain HTTP.
  • Do not expose the switch web UI to WAN — run on a management VLAN.

Limitations & Known Issues

Not yet implemented

Feature Reason
Firmware upgrade Requires binary upload (POST /firmware/upgrade). Not safe to mock — needs real hardware testing.
System time config The GET /systemtime_settings.json response format has not been captured from the switch.
SNMP proxy Planned for future release — requires SNMP agent implementation.

Known bugs / quirks

Issue Impact Mitigation
Trunk config uses hardcoded _1 suffix (write_models.rs:460-469) Setting trunk on ports 2–10 may misconfigure port 1 on real hardware. Serde renames are fixed to portTypeId_1 / Port_1_grpInd. Use the CLI set trunk command, not the TUI, for trunk config. Fix requires real hardware testing.
set network --dhcp on couples DHCP and auto-DNS Both dhcpEnabled and autoDnsEnabled are set from the single --dhcp flag. Cannot configure DHCP for IP with manual DNS (or vice versa). Use the switch web UI for split DHCP/DNS config, or a future --auto-dns flag.
TUI Mirror editor only sets monitor port Source port mirror configuration (ingress/egress per-port) is not exposed in the TUI. Setting the TUI mirror field clears all source port config on real hardware. Use sks3200 set mirror --source-ingress "1,3" for full mirror config.
TUI Loop Protection defaults not fetched from switch The TUI shows hardcoded defaults ("Off", "10", "2") rather than reading actual switch state. The GET endpoint exists but is not called. Use sks3200 set loop-protection to read before editing.
cmd_all is incomplete The show all command omits trunk, IGMP, storm, and mirror sections. Use individual show commands for complete output.

Architecture

See docs/DESIGN.md for the full design document, API reference, and data model documentation.

License

Apache 2.0

About

CLI + TUI manager for XikeStor SKS3200-8E2X switches