[Draft] Add plasma spectroscopy inverse-problem models (Langmore et al. 2022)

Status: draft for discussion. This PR adds models only. Several modelling choices are not fixed by the source paper; they are listed under Open decisions and we would welcome feedback on those.

Summary

This PR adds a family of Bayesian inverse problems from fusion-plasma spectroscopy, based on

Langmore, I., Dikovsky, M., Geraedts, S., Norgaard, P., von Behren, R. (2022). Hamiltonian Monte Carlo in Inverse Problems; Ill-Conditioning and Multi-Modality. arXiv:2103.07515.

The paper uses this problem to study two difficulties HMC meets in inverse problems: ill-conditioning and multi-modality. It is a physics forward model with a low-rank integration operator, signal-dependent noise and a non-linear geometric parameter. The paper publishes neither its data nor several constants, so all datasets are simulated from the prior with fixed seeds, and the generator scripts are included.

We propose three tiers, from an exactly Gaussian toy to the full non-linear model:

Posterior Model Data Dim. Character
plasma_linear-plasma_linear_noncentered plasma_linear_noncentered plasma_linear 40 Exactly Gaussian, well conditioned
plasma_linear-plasma_linear_centered plasma_linear_centered plasma_linear 40 Same posterior, badly conditioned
plasma_shell_lite-plasma_shell plasma_shell plasma_shell_lite 26 Non-linear, non-Gaussian, small
plasma_shell_full-plasma_shell plasma_shell plasma_shell_full 38 Non-linear, very concentrated, expensive

The model

Intuition

A hot plasma (a cloud of ions) glows, but it cannot be observed directly. Detectors look through it along straight lines (chords) and record a spectrum: intensity as a function of frequency. Three spatial fields determine the light each point emits:

  • amplitude $\mathcal A$: how brightly it emits, which sets the height of the spectral peak;
  • temperature $\mathcal T$: thermal motion Doppler-broadens the emission line, which sets the width;
  • velocity $\mathcal V$: bulk motion Doppler-shifts the line, which sets the position.
    Each detector measures only the sum along its chord, so the 2-D fields must be reconstructed from line integrals. The inverse problem is under-determined, so the answer is a posterior over fields.

Shell model (paper Sec. 2.3)

Prior. Each field is described by a radial profile on $R$ nodes $r_1 < \dots < r_R$, with a smooth Gaussian-process prior

$$ \tilde X_j = L_{pr} Z_j,\quad Z_j \sim \mathcal N(0, I_R),\quad L_{pr} L_{pr}^\top = C_{pr},\quad C_{pr}[i,k] = \exp!\Big(-\frac{(r_i-r_k)^2}{2\tau^2}\Big) + \delta,\mathbb 1_{i=k}, \qquad j \in {A, T, V}. $$

The field is constant on circles around a random centre $c \sim \mathcal N(0, \sigma_c^2 I_2)$. For pixel $p$ at $x_p \in [-1,1]^2$, with $r_p = \lVert x_p - c \rVert$, the profiles are interpolated at $r_p$ and mapped to physical quantities:

$$ \mathcal A_p = c_A,\mathcal S(\tilde X_A(r_p)),\qquad \mathcal T_p = c_T,\mathcal S(\tilde X_T(r_p)),\qquad \mathcal V_p = c_V,\tilde X_V(r_p),\qquad \mathcal S(u) = \log(1+e^u). $$

Forward model. Each pixel emits a Gaussian line in inverse frequency:

$$ E_{p}(\nu) = \frac{\mathcal A_p}{\sqrt{2\pi},w_p} \exp!\Big(-\frac{(\nu^{-1} - \tilde\nu_p^{-1})^2}{2 w_p^2}\Big),\qquad \tilde\nu_p^{-1} = \frac{1-\mathcal V_p}{\nu_0},\qquad w_p = \frac{\sqrt{\mathcal T_p}}{\nu_0}. $$

A fixed integration matrix $I \in \mathbb R^{M\times P}$ sums emission along each chord: $\mu_{m}(\nu_k) = \sum_p I_{mp} E_p(\nu_k)$.

Likelihood (paper eq. 4). There is an additive noise floor plus proportional noise representing model error:

$$ y_{mk} \sim \mathcal N\big(\mu_{mk},\ \sigma^2 + \sigma_p^2,\mu_{mk}^2\big). $$

Parameters: $Z_A, Z_T, Z_V \in \mathbb R^R$ and $c_{raw} \in \mathbb R^2$ (with $c = \sigma_c c_{raw}$), for a dimension of $3R+2$. Everything else is data.

Linear Gaussian toy (paper eqs. 1–2, Fig. 4)

The paper's own simplification keeps only the amplitude and drops the softplus and the proportional noise:

$$ x \sim \mathcal N(0, C_{pr}),\qquad y \sim \mathcal N(A x, \sigma^2 I_M). $$

The posterior is exactly Gaussian. Two parameterizations are provided:

  • centred, sampling $x$ directly;
  • non-centred, sampling $Z$ with $x = L_{pr} Z$ (the paper's "prior reparameterization", Sec. 4.2).
    With the included data, the paper's condition number (eq. 8) of the posterior is 117 (centred) against 3.2 (non-centred), which reproduces the effect shown in the paper's Fig. 4. The two models share one dataset and have the same posterior over $x$; their log densities differ by the constant $\log\lvert\det L_{pr}\rvert$.

Why these posteriors are interesting

  • Ill-conditioning. The integration operator is (numerically) low rank, so some directions are tightly constrained by the data and others only by the prior. The centred/non-centred pair isolates this effect in a case where the true posterior is known exactly.
  • Non-linearity and non-Gaussianity. The shifted centre, the softplus transforms and the signal-dependent noise all contribute.
  • Potential multi-modality. The paper shows that when the measured spectra have more peaks than the model can produce, several distinct explanations compete. The datasets here are simulated from the model, which should avoid that regime, but it is not yet verified across chains.

Data: what comes from the paper and what is chosen

The paper does not publish its data. Each dataset is a single draw from the prior followed by simulated noisy measurements, with the seed recorded in the generator script.

Shell model constants
Quantity Full Lite Source
Domain $[-1,1]^2$ same paper
Pixels $P$ 20×20 10×10 chosen
Chords $M$ 20 vertical + 20 horizontal 10 + 10 paper uses 20 vertical; horizontal set added (see D6)
Frequencies $K$ 60 30 chosen (paper: ≈200)
Window 229.5–229.9 same read off paper Fig. 3
$\nu_0$ 229.7 same inferred (C III line, Fig. 3)
$\tau$ 0.2 same paper (one of the two values used)
$\delta$ 0.001 same paper
Radial nodes $R$, range 12 on [0, 3] 8 on [0, 2] chosen to cover all pixel distances
$\sigma_c$ 0.1 same chosen
$\sigma$ 5 15 within the paper's range 1.25–15
$\sigma_p$ 0.05 same chosen
$c_A$ 7e-4 2e-4 chosen: peak signal ≈10³ (full), ≈3·10² (lite)
$c_T$ 2e-8 same chosen: line width ≈1.5–4.5 frequency spacings
$c_V$ 1e-4 same chosen: shift ≈ one line width per unit of $\tilde X_V$
Peak signal-to-noise ≈20 ≈15 resulting
Linear toy constants
Quantity Value Source
$N$, $M$ 40, 20 paper (Fig. 1/4)
$\tau$, $\delta$, $\sigma$ 0.2, 0.001, 1 paper (Fig. 4)
Grid 40 equispaced points on [−1, 1] chosen
Forward matrix $A$ Each row is a Gaussian-weighted local average (width 0.2), rows sum to 1 chosen; the paper's $A$ is not given

Open decisions

These are points where the paper is ambiguous or silent. For each, we state what we implemented and the alternative. Feedback welcome, particularly on D1–D3.

# Question Implemented Alternative / note
D1 Meaning of $\delta$ in the prior covariance (paper eq. 5 prints "$+\delta$") $\delta$ added on the diagonal ($C + \delta I$) Literal reading adds $\delta$ to every entry, a rank-one shift that does not do what the paper says it is for (preventing small eigenvalues)
D2 Line width $w$ $w = \sqrt{\mathcal T}/\nu_0$, as printed $\sqrt{\mathcal T/\nu_0}$ is also a possible reading of the PDF; it would change the scale of $c_T$
D3 Shell or slab spatial structure Shell only (the paper's main case) Slab (fields constant on chord-aligned strips) is simpler and could be added later as another model
D4 One centre for all three fields, or one each One shared centre Prior scale $\sigma_c$ and mean not given in the paper; possibly in its ref. [5], Dikovsky et al. (2021), Phys. Plasmas 28, 062503
D5 Interpolation of radial profiles Piecewise linear, constant beyond the last node The log density has kinks where $r_p$ crosses a node. A smooth scheme (e.g. cubic spline) would be cleaner for HMC but harder to match exactly across Stan/PyMC
D6 Chord geometry Vertical and horizontal chords With vertical chords only (as in Fig. 2), the likelihood is exactly symmetric under $c_y \to -c_y$, which builds in a bimodality
D7 Noise parameters $\sigma$, $\sigma_p$ fixed (data) They could be inferred instead, which adds two parameters
D8 Physical constants $c_A, c_T, c_V$, grids Chosen so the simulated spectra resemble paper Fig. 3 Not given in the paper
D9 Linear-toy forward matrix Gaussian local-average rows Not given in the paper
D10 Include both linear parameterizations? Yes, as a centred/non-centred pair (like eight_schools) Only the non-centred one could be added
D11 Full shell dataset Included Expensive to sample

A purely numerical reformulation: the code uses $\tilde\nu^{-1} = (1-\mathcal V)/\nu_0$ directly instead of $\tilde\nu = \nu_0/(1-\mathcal V)$. This is mathematically identical and avoids a division by zero at $\mathcal V = 1$.

Questions

  1. Both shell datasets come from one generator script with a lite/full switch. Is it fine to have one script per data-raw folder that calls the shared generator, or should the code be duplicated?